Case Dossier 03 · Sustainable Civic Timber

Helmholtz Birch & Sheep-Wool Slatted Wall Systems

Contemporary Nordic public buildings favor triple-glazed curtain walls, board-formed concrete, and polished terrazzo floors—surfaces whose random-incidence absorption coefficients rarely exceed `alpha = 0.03`. Left untreated, municipal libraries and school dining commons quickly escalate via the Lombard vocal-effort effect above 76 dBA during peak hours.

1. Staggered Slot Ratios Preventing High-Frequency Glare

Uniformly spaced wooden battens act as narrow-band Helmholtz resonators peaking sharply around 500–800 Hz while reflecting 2–4 kHz consonant energy like a hard mirror. For the Tampere reading atrium, we milled three interleaved slat widths (`28 mm`, `44 mm`, and `68 mm` solid heat-treated spruce) over variable 12 mm to 26 mm reveal gaps backed by non-woven black flax scrim and 75 mm carded Nordic sheep wool (`flow resistivity sigma = 14,500 Pa·s/m²`).

2. Impedance Tube Validation (ISO 10534-2)

Normal-incidence standing-wave impedance tube prototypes verified smooth broadband absorption prior to full-scale carpentry fabrication:

Assembly Configuration 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz 4 kHz
Type A: 24% Open Area + 75 mm Wool 0.38 0.74 0.92 0.88 0.76 0.64
Type B: Tuned Low-Mid + 150 mm Plenum 0.66 0.89 0.84 0.62 0.48 0.41
Indoor Air Quality & Fire Rating: All timber slats are treated with zero-VOC silicate mineral fire retardants meeting Euroclass `B-s1, d0` and Finnish `M1` low-emission building material certification.